Svoboda | Graniru | BBC Russia | Golosameriki | Facebook

CETAL | Infrastructure

CETAL on EERTIS website: https://eertis.eu/errf-2300-000k-1078

CETAL-PW – Ultraintense Laser Infrastructure
CETAL-PW Laser System

1 PW laser system - Thales, France

  • Ti:Sapphre laser - 800 nm
  • Pulse duration - 25 fs
  • 25 J at 0.1 Hz
  • 1 J at 10 Hz
  • Beam transport - Ardop, France
  • Interaction Chamber - Astra Gemini, RAL UK
  • Femtosecond laser beam characterization devices
  • Electron beam detectors, X-ray detectors

TEWALAS Laser system

Terawatt Class Laser system - Amplitude, France
  • Peak power: 15 TW
  • Ti:Sapphire laser: 800 nm
  • Repetition rate: 10 Hz
  • Pulse energy before compressor: > 600 mJ
  • Pulse duration: 23-27 fs (typicaly 25 fs)

GPU SERVER


CETAL-LaMP – Laser material processing
Picosecond laser microprocessing

Laser source Lumera HyperRapid 50
  • Wavelengths 1064, 532, 355 nm
  • 500 kHz
  • < 10ps
  • Translation stages: PlanarDL 200XY- Aerotech Two Axis
  • 3 laser scanning heads for 3 wavelengths
  • CAD, G-script

CO2 laser

Tunable CW CO2 laser

  • Laser power : 1 kW
  • Wavelength: 9.2-11.2 ?m
  • Beam diameter : 13 mm diameter

3D Laser Lithography

Photonic Profesional - Nanoscribe GmbH, Germany

  • Femtosecond fiber laser Toptica - 120 fs
  • Zeiss inverted microscope
  • PIMars piezo stage 300x300x300 m3
  • Translation stage 100x100 mm2
  • Microscope Objectives: 100x oil, 100x DiLL, 63x, 20x.

Laser macroprocessing

Lasers:
  • TruDisk 3001
  • TruPulse 62
  • TruMicro 7050

Workstations:

  • TruLaser Cell 3010
  • TruLaser Robot 5020

Cleanroom ISO7

The cleanroom is equiped with samples preparation area with following equipments:

- Laminar fume hood for solvents
- Speencoater
- Ultrasonic bath
- Plasma cleaner
- Optical microscope


CETAL-PhIL – Photonic Investigation Laboratory
Lambdameter

  • ..



Tunable picosecond laser

Tunable picosecond laser
NKT SuperExtreme EXW-4

  • Tunability: 450-2400 nm
  • SuperK filter: 450-800 nm
  • Repetition rate: 78 MHz
  • Polarization: unpolarized
  • Beam output: gaussian, single mode
  • Total power: 2W

Thermovision Camera


Fluorescence spectroscopy - OPO laser

Tunable ns Laser Sunlite EX OPO with FX-1 from Continuum, USA

  • Laser tunability with no degeneracy gap : 445 nm - 1750 nm
  • FX-1 frequency doubling option for 222.5 nm to 450 nm operation
  • Pump Energy 350 mJ
  • Linewidth 0.075 cm-1
  • Pulsewidth 3-6 ns
  • Energy at peak 50 mJ at 550nm

Vibrometry

Shock and vibration system ES-6-230
Dongling Vibration Test Instrument Co.Ltd, China, yes

  • Frequency range: 5-3000 Hz
  • Max Displacement: 50 mm
  • Max Acceleration: 100 G
  • Max velocity: 2.8 m/s
  • Max Load support: 300 kg
  • Supports shocks and vibrations in both horizontal and vertical axes.

THz Spectroscopy

THz Pulsed Imaging and Spectroscopy - TPS Spectra 3000 from TeraView, UK

  • Terahertz transmission and reflectance measurements on solids;
  • Liquids, suspensions, slurries and films;
  • Spectral Range: 0.06 THz to 4 THz (2 cm-1 - 120 cm-1);
  • ATR modules for optimized measurements on as little as 1 mg solid sample;
  • RIM module for reflectance mapping;
  • XY transmittance module for transmittance mapping;
  • GaAs antenna used for emitter and detector for ambient temperature operation.

Chemistry Laboratory


Laser Induced Breakdown Spectroscopy - LIBS

Laser Breakdown Spectroscopy System LIBS-6 from Applied Photoncs, UK

  • Wavelength Range : 200-900 nm
  • Laser : Quantel Big Sky CFR 1064 nm
  • Max Energy : 197 mJ
  • Pulse frequency : 1-20 Hz
  • Contains 3 axis translation stage with video camera
  • Sample Chamber dimensions 260 x 260 x 320 mm
  • Accessories: Modular sample chambers designed for liquids, solids and powders.

Frequency comb

  • ..



Raman Spectroscopy

Dispersive Raman Microscope JASCO NRS-7200

  • 532 nm, 633 nm si 785 nm lasers
  • Maximum resolution: 0.3 cm-1
  • Measurement range: 5-8000 cm-1
  • XYZ automatic stage with 100 nm resolution
  • Aberation-corrected Czerny-Turner monochromator (f=500 mm)

Atomic absorption spectrometry

  • Flame absorption (air - acetylene and acetylene - nitrous oxide).
  • Available lamps : Ag, Au, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Pt, Sn, Ti, Zn.

Spectro-radiometer

Double Monochromator Spectroradiometer OL 750 from Gooch&Housego, Orlando - USA

  • Spectral range: 200- 30000 nm

Configurations:

  • Source Spectral Analysis
  • Detector Responsivity
  • Diffuse Spectral Reflectance
  • Spectral Transmittance @ 0 deg.
  • Transmittance Goniometer
  • Specular Reflectance Goniometer
  • BRDF

Photonic investigation of bio-materials

  • Optical Microscope Leica DM4000 B LED,
  • Vertical laminar airflow cabinet BSC-EN I - II.



Spectrofluorometer Fluorolog-3 HORIBA

DESCRIPTION:

  • Excitation source: 450 W xenon short arc, mounted vertically in an air-cooled housing. Light collection and focusing by an off-axis mirror for maximum efficiency at all wavelengths. Optional pulsed lamp or laser port interface available.
  • Single-grating excitation monochromator
  • Single-grating emission monochromator
  • Automatic slits
  • Room-temperature R928P detector
  • Monochromators: Single-grating monochromators (standard). Monochromators are f/3.6 Czerny-Turner design with kinematic classically-ruled gratings and all-reflective optics. Optional double-grating units are available for highest stray-light rejection and sensitivity.
  • The following specifications are based on 1200-grooves/mm gratings:
  • Resolution 0.3 nm
  • Accuracy �0.5 nm
  • Step size 0.0625 nm min. to 100 nm max.

ACCELERATOR
Accelerator

ACCELERATOR - IOSIN-CETAL