Svoboda | Graniru | BBC Russia | Golosameriki | Facebook
Jump to content

Talk:Electron therapy

Page contents not supported in other languages.
From Wikipedia, the free encyclopedia
This article is rated Start-class on Wikipedia's content assessment scale.
It is of interest to the following WikiProjects:WikiProject iconMedicine: Hematology-oncology / Radiology Mid‑importance
WikiProject iconThis article is within the scope of WikiProject Medicine, which recommends that medicine-related articles follow the Manual of Style for medicine-related articles and that biomedical information in any article use high-quality medical sources. Please visit the project page for details or ask questions at Wikipedia talk:WikiProject Medicine.
MidThis article has been rated as Mid-importance on the project's importance scale.
Taskforce icon
This article is supported by the Hematology-oncology task force (assessed as Mid-importance).
Taskforce icon
This article is supported by the Radiology task force (assessed as Mid-importance).
Note icon
An editor has requested that an image or photograph be added to this article.

Rising dose?

[edit]

Why would the dose rise first with increasing depth? I know that particles are slowing down over time and so when they reach a certain lower speed the effects can get different (like they can be captured), but as far as I know photons can only interact with matter once, they can't lose only part of their energy, and thus the dose must be decreasing exponentially if the same matter is present at every point. So the shown graphic needs an explanation why the dose is first getting higher with increasing depth. Also, I'm missing a citation for the data that was used to create the graph.--Pflanze2 (talk) 09:23, 1 November 2014 (UTC)[reply]

It is due to lack of electronic equilibrium at the surface. Nearly all the dose deposited following a photon interaction actually comes from the electrons liberated in Compton and PhotoElectric interactions. These have a range of 0.5-3cm depending on energy, and are predominantly forward oriented. So the dose does not reach a maximum until the range of these electrons is reached. — Preceding unsigned comment added by 194.176.105.133 (talk) 15:38, 11 December 2014 (UTC)[reply]