Moment-resisting frame

From Wikipedia, the free encyclopedia

Moment-resisting frame is a rectilinear assemblage of beams and columns, with the beams rigidly connected to the columns.

Resistance to lateral forces is provided primarily by rigid frame action – that is, by the development of bending moment and shear force in the frame members and joints. By virtue of the rigid beam–column connections, a moment frame cannot displace laterally without bending the beams or columns depending on the geometry of the connection. The bending rigidity and strength of the frame members is therefore the primary source of lateral stiffness and strength for the entire frame.[1]

The 1994 Northridge earthquake revealed a common flaw in steel-frame construction — poorly welded moment connections — and building codes were revised to strengthen them.[2]

YouTube Encyclopedic

  • 1/3
    Views:
    1 650
    58 923
    15 271
  • Multi-Story Special Moment Frame
  • How to Install a Special Moment Frame in Soft-Story Building Retrofits
  • Strong Frame® Ordinary Moment Frame Installation

Transcription

Early history

Steel moment-resisting frames have been in use for more than one hundred years, dating to the earliest use of structural steel in building construction. Steel building construction with the frame carrying the vertical loads initiated with the Home Insurance Building in Chicago, a 10-story structure constructed in 1884 with a height of 138 ft, often credited with being the first skyscraper. This and other tall buildings in Chicago spawned an entire generation of tall buildings, constructed with load bearing steel frames supporting concrete floors and non-load bearing, unreinforced masonry infill walls at their perimeters. Framing in these early structures typically utilized "H" shapes built up from plates, and "L" and "Z" sections.[3]

References

  1. ^ Bruneau, Michel. et al., (2011). Ductile Design of Steel Structures. McGraw-Hill Companies, Inc. ISBN 978-0-07-162395-7.page 347
  2. ^ "20 Years After Northridge Quake, Buildings Remain Vulnerable."
  3. ^ Hamburger, Ron. et al., (2009). Seismic Design of Steel Structures. National Institute of Standards and Technology . NIST GCR 09-917-3.page 3
This page was last edited on 10 September 2019, at 19:43
Basis of this page is in Wikipedia. Text is available under the CC BY-SA 3.0 Unported License. Non-text media are available under their specified licenses. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc. WIKI 2 is an independent company and has no affiliation with Wikimedia Foundation.