Svoboda | Graniru | BBC Russia | Golosameriki | Facebook

To install click the Add extension button. That's it.

The source code for the WIKI 2 extension is being checked by specialists of the Mozilla Foundation, Google, and Apple. You could also do it yourself at any point in time.

4,5
Kelly Slayton
Congratulations on this excellent venture… what a great idea!
Alexander Grigorievskiy
I use WIKI 2 every day and almost forgot how the original Wikipedia looks like.
Live Statistics
English Articles
Improved in 24 Hours
Added in 24 Hours
Languages
Recent
Show all languages
What we do. Every page goes through several hundred of perfecting techniques; in live mode. Quite the same Wikipedia. Just better.
.
Leo
Newton
Brights
Milds

Surgical smoke

From Wikipedia, the free encyclopedia

A surgeon using an electrosurgical unit, a common source of surgical smoke.

Surgical smoke is the by-product produced by electrosurgery, laser tissue ablation, or other surgical techniques. Surgical smoke, as a health threat to those exposed to it, has become a growing concern.[1] Studies have demonstrated, depending on several factors, it may contain carcinogens, mutagens, irritant chemicals, live viruses and bacteria, and viable malignant cells. [1][2][3] These all pose a theoretical and demonstrable risk of harming patients or operating room personnel upon exposure.[3] Other names for surgical smoke are cautery smoke, plume, diathermy plume, or, sometimes, aerosols produced during surgery, vapor contaminants, or air contaminants.[4]

Electrosurgery and laser ablation are the most common sources of surgical smoke.[3] Heat generated during surgery causes cell membranes to heat and rupture, releasing cellular debris alongside water vapor.[3] Surgical smoke is composed of 95% water and the remaining 5% contains byproducts of combustion and cellular debris.[3] The negative health effects due to exposure of surgical smoke is attributed to what is contained in the 5%.[3] The size of particles within the plume of smoke varies depending on the device that generated it.[3] On average electrosurgery produces particles that are .07 μm, while laser ablation generates larger particles that are .31 μm on average.[3][5] Particles smaller than 2 micrometers are able to reach the alveoli within the lower respiratory tract and, if 0.1 μm or smaller, can enter systemic circulation.[3][5]

The amount of cellular debris in a smoke plume changes with the tissue being cauterized. The liver has been shown to generate the largest amount of particles.[3] Other than type of tissue and surgical device, operating room airflow can also affect smoke exposure.[5][3] read more on [1]

YouTube Encyclopedic

  • 1/2
    Views:
    3 099
    7 436
  • Skin Resurfacer(tm) Treating a Seborrheic Keratosis on the Forehead
  • Skin Resurfacer(tm) Treating a Seborrheic Keratosis on the Chin

Transcription

Health impact

The cellular debris included in surgical smoke has been shown to include live bacteria and viruses, and even viable malignant cells.[3] The negative effects of surgical smoke exposure to humans is less documented than its effects on animals.[5] Acute negative effects due to the exposure of surgical smoke may include headaches, eye and throat irritation, nausea, drowsiness and dizziness.[3][1] Operating personnel have been found to have an increased risk of chronic pulmonary and upper respiratory health problems compared to other populations.[3] Human papilloma virus has been the only virus to demonstrate spreading via surgical smoke, despite concern for other viruses.[6][5] Besides potential health effects, surgical smoke can visually obscure the surgical field.[1]

The amount of benzene detected in operating room air has been shown to be greater than the recommended exposure limits established by the National Institute of Occupational Safety and Health (NIOSH) and the Occupational Safety and Health Administration (OSHA) which are 0.1 mg/m3 and 0.2 mg/m3 respectively.[3]

Minimizing exposure

The pores on a standard surgical mask are 5-15 μm in diameter, which is inadequate in completely protecting operating room personnel from the harms of surgical smoke.[3][5] Due to studies evaluating particles passing through standard surgical masks, some suggested that more effective masks such as HEPA-filters and N95 should be used to provide better protection from cellular debris.[3] Others suggest that even N95s are ineffective at reducing health risks associated with ultra-fine particulate matter.[5] Particulate matter is not the only pollutant produced by surgical smoke. Various volatile organic compounds are also created. Masks will be ineffective against gaseous compounds unless specialized filtration is used such as activated carbon or catalytic mesh.

Smoke evacuation devices (SED) are the most effective at reducing exposure of surgical smoke.[7][3] However, the use of these devices is not widespread.[5] Lack of SED usage has been attributed to low amounts of education surrounding the risks of surgical smoke and the surgeons' unwillingness to adopt such devices.[3][5][6] It has been suggested that the bulkiness of these devices and noise are factors contributing to lack of surgeons' enthusiasm for SED usage.[3][6]

References

  1. ^ a b c d Georgesen C, Lipner SR (October 2018). "Surgical smoke: Risk assessment and mitigation strategies". Journal of the American Academy of Dermatology. 79 (4): 746–755. doi:10.1016/j.jaad.2018.06.003. PMID 29902546. S2CID 49207634.
  2. ^ Fitzgerald JE, Malik M, Ahmed I (February 2012). "A single-blind controlled study of electrocautery and ultrasonic scalpel smoke plumes in laparoscopic surgery". Surgical Endoscopy. 26 (2): 337–42. doi:10.1007/s00464-011-1872-1. PMID 21898022. S2CID 10211847.
  3. ^ a b c d e f g h i j k l m n o p q r s t Liu Y, Song Y, Hu X, Yan L, Zhu X (2019). "Awareness of surgical smoke hazards and enhancement of surgical smoke prevention among the gynecologists". Journal of Cancer. 10 (12): 2788–2799. doi:10.7150/jca.31464. PMC 6584931. PMID 31258787.
  4. ^ Watson DS. "Surgical Smoke: What Do We Know" (PDF). Covidien.
  5. ^ a b c d e f g h i Swerdlow BN (August 2020). "Surgical smoke and the anesthesia provider". Journal of Anesthesia. 34 (4): 575–584. doi:10.1007/s00540-020-02775-x. PMID 32296937. S2CID 215760723.
  6. ^ a b c Limchantra IV, Fong Y, Melstrom KA (October 2019). "Surgical Smoke Exposure in Operating Room Personnel: A Review". JAMA Surgery. 154 (10): 960–967. doi:10.1001/jamasurg.2019.2515. PMID 31433468. S2CID 201116813.
  7. ^ Carroll, Gregory T.; Kirschman, David L. (2023-01-23). "Catalytic Surgical Smoke Filtration Unit Reduces Formaldehyde Levels in a Simulated Operating Room Environment". ACS Chemical Health & Safety. 30 (1): 21–28. doi:10.1021/acs.chas.2c00071. ISSN 1871-5532.

Further reading

This page was last edited on 18 January 2024, at 21:01
Basis of this page is in Wikipedia. Text is available under the CC BY-SA 3.0 Unported License. Non-text media are available under their specified licenses. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc. WIKI 2 is an independent company and has no affiliation with Wikimedia Foundation.