PreprintArticleVersion 1Preserved in Portico This version is not peer-reviewed
Characterization and Correction of the Geometric Errors in Using Confocal Microscope for Extended Topography Measurement. Part II: Experimental Study and Uncertainty Evaluation
Wang, C.; Gómez, E.; Yu, Y. Characterization and Correction of the Geometric Errors using a Confocal Microscope for Extended Topography Measurement, Part II: Experimental Study and Uncertainty Evaluation. Electronics2019, 8, 1217.
Wang, C.; Gómez, E.; Yu, Y. Characterization and Correction of the Geometric Errors using a Confocal Microscope for Extended Topography Measurement, Part II: Experimental Study and Uncertainty Evaluation. Electronics 2019, 8, 1217.
Wang, C.; Gómez, E.; Yu, Y. Characterization and Correction of the Geometric Errors using a Confocal Microscope for Extended Topography Measurement, Part II: Experimental Study and Uncertainty Evaluation. Electronics2019, 8, 1217.
Wang, C.; Gómez, E.; Yu, Y. Characterization and Correction of the Geometric Errors using a Confocal Microscope for Extended Topography Measurement, Part II: Experimental Study and Uncertainty Evaluation. Electronics 2019, 8, 1217.
Abstract
This paper presents the experimental implementations of the mathematical models and algorithms developed in Part I. Two experiments are carried out. The first experiment aims at the determinations of the correction coefficients of the mathematical model. The dot grid target is measured and the measurement data are processed by our developed and validated algorithms introduced in Part I. The values of the coefficients are indicated and analysed. Uncertainties are evaluated with implementation of the Monte Carlo method. The second experiment measures a different area of the dot grid target. The measurement results are corrected according to the coefficients determined in the first experiment. The mean residual between the measured points and their corresponding certified values reduced 29.6% after the correction. The sum of squared errors reduced 47.7%. The methods and the algorithms for raw data processing, such as data partition, fittings of dots’ centres, K-means clustering, etc., are the same for both two experiments. The experimental results demonstrate that our method for the correction of the errors produced by the movement of lateral stage of confocal microscope is meaningful and practicable.
Copyright:
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.