Socrates, T.; Krisai, P.; Meienberg, A.; Mayr, M.; Burkard, T.; Vischer, A.S. Effect of Cuff Inflation on Blood Pressure, Arousals, Sleep Efficiency, and Desaturations: Sub-Analysis of the VAST Pilot Study. Diagnostics2023, 13, 2874.
Socrates, T.; Krisai, P.; Meienberg, A.; Mayr, M.; Burkard, T.; Vischer, A.S. Effect of Cuff Inflation on Blood Pressure, Arousals, Sleep Efficiency, and Desaturations: Sub-Analysis of the VAST Pilot Study. Diagnostics 2023, 13, 2874.
Socrates, T.; Krisai, P.; Meienberg, A.; Mayr, M.; Burkard, T.; Vischer, A.S. Effect of Cuff Inflation on Blood Pressure, Arousals, Sleep Efficiency, and Desaturations: Sub-Analysis of the VAST Pilot Study. Diagnostics2023, 13, 2874.
Socrates, T.; Krisai, P.; Meienberg, A.; Mayr, M.; Burkard, T.; Vischer, A.S. Effect of Cuff Inflation on Blood Pressure, Arousals, Sleep Efficiency, and Desaturations: Sub-Analysis of the VAST Pilot Study. Diagnostics 2023, 13, 2874.
Abstract
The influence of cuff inflations on nighttime measurements during 24h ambulatory blood pressure (BP) measurements is unknown. We investigated the potential effect of cuff-inflations on asleep parameters using measurements taken simultaneously with a cuffless device using pulse-transit-time (PTT). On the first day of measurement, standard cuff-based 24h BP and cuf-fless measurements were simultaneously performed on right and left arms (CUFF/PTT-D). 1-2 days after the first measurement, the cuffless device was worn alone (PTT-D). Only data from the cuffless device was analyzed. The following mean asleep parameters were analyzed: systolic and diastolic BP, arousals, sleep efficiency, total arousals, arousal per hour and desaturations. 21 in-dividuals were prospectively enrolled. Mean (SD) age was 47(±15) years and 57% were female. Mean systolic asleep BP for the during CUFF/PTT-D and during PTT-D were 131(±21) and 131(±26) mmHg respectively. Mean diastolic asleep BP values during CUFF/PTT-D and during PTT-D were 80(±14) and 84(±14) mmHg respectively (p=0.860, p=0.100 respectively). Systolic and diastolic asleep mean difference was 0.1 (±18.0) and -3.6 (±9.8) mmHg, respectively. There were significantly more total arousals during PTT-D (p=0.042). There was no significant difference seen in sleep efficiency (p=0.339) or desaturations (p=0.896) between the two measurements. We could not show any significant impact from cuff inflations during asleep PTT-D measurements.