PreprintArticleVersion 1Preserved in Portico This version is not peer-reviewed
Detection and Quantification of Bisphenol A in Surface Water Using Absorbance-Transmittance and Fluorescence Excitation-Emission Matrices (A-TEEM) Coupled with Multi-Way Techniques
Ingwani, T.; Chaukura, N.; Mamba, B.B.; Nkambule, T.T.I.; Gilmore, A.M. Detection and Quantification of Bisphenol A in Surface Water Using Absorbance–Transmittance and Fluorescence Excitation–Emission Matrices (A-TEEM) Coupled with Multiway Techniques. Molecules2023, 28, 7048.
Ingwani, T.; Chaukura, N.; Mamba, B.B.; Nkambule, T.T.I.; Gilmore, A.M. Detection and Quantification of Bisphenol A in Surface Water Using Absorbance–Transmittance and Fluorescence Excitation–Emission Matrices (A-TEEM) Coupled with Multiway Techniques. Molecules 2023, 28, 7048.
Ingwani, T.; Chaukura, N.; Mamba, B.B.; Nkambule, T.T.I.; Gilmore, A.M. Detection and Quantification of Bisphenol A in Surface Water Using Absorbance–Transmittance and Fluorescence Excitation–Emission Matrices (A-TEEM) Coupled with Multiway Techniques. Molecules2023, 28, 7048.
Ingwani, T.; Chaukura, N.; Mamba, B.B.; Nkambule, T.T.I.; Gilmore, A.M. Detection and Quantification of Bisphenol A in Surface Water Using Absorbance–Transmittance and Fluorescence Excitation–Emission Matrices (A-TEEM) Coupled with Multiway Techniques. Molecules 2023, 28, 7048.
Abstract
In the present protocol, we determined the presence and concentrations of bisphenol A (BPA) spiked in surface water samples using EEM fluorescence spectroscopy in conjunction with modelling using partial least squares (PLS) and parallel factor (PARAFAC). PARAFAC modelling of the EEM fluorescence data obtained from surface water samples contaminated with BPA unraveled four fluorophores including BPA. The best outcomes for BPA concentration (R2 = 0:996; Standard deviation to prediction error's root mean square ratio (RPD) = 3.41; and a Pearson's r value of 0.998). With these values of R2 and Pearson's r, the PLS model showed a strong correlation between the predicted and measured BPA concentrations. The detection and quantification limits of the methods were 3.512 and 11.708 micro molar (µM), respectively. In conclusion, BPA can be precisely detected and its concentration in surface water predicted using the PARAFAC and PLS models developed in this study and fluorescence EEM data collected from BPA-contaminated water. It is necessary to spatially relate surface water contamination data with other datasets in order to connect drinking water quality issues with health, environmental restoration, and environmental justice concerns.
Keywords
method development; optimisation and validation; parallel factor modelling; partial least squares modelling
Subject
Chemistry and Materials Science, Analytical Chemistry
Copyright:
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.