PreprintArticleVersion 1Preserved in Portico This version is not peer-reviewed
Value of Carotid Corrected Flow Time (FTc) or Changes Value of FTc Could Be More Useful in Predicting Fluid Responsiveness Undergoing Robot-Assisted Gynecologic Surgery
Version 1
: Received: 24 August 2023 / Approved: 24 August 2023 / Online: 28 August 2023 (10:32:40 CEST)
How to cite:
Tang, X.; Liang, J.; Chen, Q.; Yang, T.; Liu, H. L. Value of Carotid Corrected Flow Time (FTc) or Changes Value of FTc Could Be More Useful in Predicting Fluid Responsiveness Undergoing Robot-Assisted Gynecologic Surgery. Preprints2023, 2023081763. https://doi.org/10.20944/preprints202308.1763.v1
Tang, X.; Liang, J.; Chen, Q.; Yang, T.; Liu, H. L. Value of Carotid Corrected Flow Time (FTc) or Changes Value of FTc Could Be More Useful in Predicting Fluid Responsiveness Undergoing Robot-Assisted Gynecologic Surgery. Preprints 2023, 2023081763. https://doi.org/10.20944/preprints202308.1763.v1
Tang, X.; Liang, J.; Chen, Q.; Yang, T.; Liu, H. L. Value of Carotid Corrected Flow Time (FTc) or Changes Value of FTc Could Be More Useful in Predicting Fluid Responsiveness Undergoing Robot-Assisted Gynecologic Surgery. Preprints2023, 2023081763. https://doi.org/10.20944/preprints202308.1763.v1
APA Style
Tang, X., Liang, J., Chen, Q., Yang, T., & Liu, H. L. (2023). Value of Carotid Corrected Flow Time (FTc) or Changes Value of FTc Could Be More Useful in Predicting Fluid Responsiveness Undergoing Robot-Assisted Gynecologic Surgery. Preprints. https://doi.org/10.20944/preprints202308.1763.v1
Chicago/Turabian Style
Tang, X., Tingjun Yang and Hong liang Liu. 2023 "Value of Carotid Corrected Flow Time (FTc) or Changes Value of FTc Could Be More Useful in Predicting Fluid Responsiveness Undergoing Robot-Assisted Gynecologic Surgery" Preprints. https://doi.org/10.20944/preprints202308.1763.v1
Abstract
This prospective study aimed to evaluate the ability of point-of-care Doppler ultrasound measurements of carotid-corrected flow time and changes in corrected carotid flow time (FTc) induced by volume expansion to predict fluid responsiveness in patients undergoing robot-assisted gynecological surgery in a modified head-down lithotomy position. FTc was measured using Doppler images of the common carotid artery before and after volume expansion. The stroke volume index at each time point was recorded using the MostCare instrument. Fluid responsiveness was defined as a stroke volume index ≥10% increase after volume expansion. Half (50%) of the 52 patients responded positively. The areas under the receiver operating characteristic curves measured to predict fluid responsiveness for the corrected carotid flow time and changes in the FTc were 0.82 [95% confidence interval:0.705–0.937; P < 0.0001] and 0.67 (95% confidence interval:0.520–0.815; P < 0.05), respectively. The optimal cut-off value for the FTc and the change in FTc were 356.5 ms and 19.5 ms, respectively. FTc is a more reliable predictor of fluid responsiveness than FTc induced by volume expansion in gynecological patients undergoing robot-assisted laparoscopic surgery in the modified head-down lithotomy position.
Keywords
Doppler ultrasound; Corrected time flow; Fluid responsiveness; Robotics
Subject
Medicine and Pharmacology, Anesthesiology and Pain Medicine
Copyright:
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.