Mousavi, H.; Dauly, G.; Dieuset, G.; El Merhie, A.; Ismailova, E.; Wendling, F.; Al Harrach, M. Tuning Microelectrodes’ Impedance to Improve Fast Ripples Recording. Bioengineering2024, 11, 102.
Mousavi, H.; Dauly, G.; Dieuset, G.; El Merhie, A.; Ismailova, E.; Wendling, F.; Al Harrach, M. Tuning Microelectrodes’ Impedance to Improve Fast Ripples Recording. Bioengineering 2024, 11, 102.
Mousavi, H.; Dauly, G.; Dieuset, G.; El Merhie, A.; Ismailova, E.; Wendling, F.; Al Harrach, M. Tuning Microelectrodes’ Impedance to Improve Fast Ripples Recording. Bioengineering2024, 11, 102.
Mousavi, H.; Dauly, G.; Dieuset, G.; El Merhie, A.; Ismailova, E.; Wendling, F.; Al Harrach, M. Tuning Microelectrodes’ Impedance to Improve Fast Ripples Recording. Bioengineering 2024, 11, 102.
Abstract
Epilepsy is a chronic neurological disorder characterized by recurring seizures resulting from abnormal neuronal hyperexcitability. In the case of pharmacoresistant epilepsy requiring resection surgery, identifying the epileptogenic zone (EZ) is crucial. Fast ripples (FRs; 200-600 Hz) are one of the promising biomarkers that can aid in EZ delineation. However, recording FRs requires small surface electrodes. These microelectrodes suffer from high impedance, which significantly impacts FR observability and detection. In this study, we explored the potential of a conductive polymer coating to enhance FR observability. We employed biophysical modeling to compare two types of microelectrodes: Gold (Au) and Au coated with the conductive polymer poly(3,4-ethylenedioxythiophene)-poly(styrene sulfonate) (Au/PEDOT:PSS). These electrodes were then implanted in the CA1 hippocampal neural network of epileptic mice to record FRs during epileptogenesis. Results showed that polymer-coated electrodes demonstrate two-order lower impedance and a higher transfer function amplitude and cut-off frequency. Consequently, FRs recorded with the PEDOT:PSS coated microelectrode yielded significantly higher signal energy compared to the uncoated one. The coating with PEDOT:PSS improved the observability of recorded FRs and therefore their detection. This work paves the way for the development of signal-specific microelectrodes design allowing better targeting of pathological biomarkers.
Keywords
Epilepsy; Fast ripples; conductive polymers; microelectrodes; electrode tissue interface; PEDOT/PSS
Subject
Engineering, Bioengineering
Copyright:
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.