14 pages, 3771 KiB  
Article
Characterization of a Modified Clinical Linear Accelerator for Ultra-High Dose Rate Beam Delivery
by Umberto Deut, Aurora Camperi, Cristiano Cavicchi, Roberto Cirio, Emanuele Maria Data, Elisabetta Alessandra Durisi, Veronica Ferrero, Arianna Ferro, Simona Giordanengo, Oscar Martì Villarreal, Felix Mas Milian, Elisabetta Medina, Diango M. Montalvan Olivares, Franco Mostardi, Valeria Monti, Roberto Sacchi, Edoardo Salmeri and Anna Vignati
Appl. Sci. 2024, 14(17), 7582; https://doi.org/10.3390/app14177582 - 27 Aug 2024
Viewed by 538
Abstract
Irradiations at Ultra-High Dose Rate (UHDR) regimes, exceeding 40 Gy/s in single fractions lasting less than 200 ms, have shown an equivalent antitumor effect compared to conventional radiotherapy with reduced harm to normal tissues. This work details the hardware and software modifications implemented [...] Read more.
Irradiations at Ultra-High Dose Rate (UHDR) regimes, exceeding 40 Gy/s in single fractions lasting less than 200 ms, have shown an equivalent antitumor effect compared to conventional radiotherapy with reduced harm to normal tissues. This work details the hardware and software modifications implemented to deliver 10 MeV UHDR electron beams with a linear accelerator Elekta SL 18 MV and the beam characteristics obtained. GafChromic EBT XD films and an Advanced Markus chamber were used for dosimetry characterization, while a silicon sensor assessed the machine’s beam pulses stability and repeatability. The dose per pulse, average dose rate and instantaneous dose rate in the pulse were evaluated for four experimental settings, varying the source-to-surface distance and the beam collimation, i.e., with and without the use of a cylindrical applicator. The results showed a dose per pulse from 0.6 Gy to a few tens of Gy and an average dose rate up to 300 Gy/s. The obtained results demonstrate the possibility to perform in vitro radiobiology experiments and test new technologies for beam monitoring and dosimetry at the upgraded LINAC, thus contributing to the electron UHDR research field. Full article
Show Figures

Figure 1

13 pages, 2655 KiB  
Article
Multi-Point Sensing via Organic Optical Fibres for FLASH Proton Therapy
by Crystal Penner, Samuel Usherovich, Sophia Andru, Camille Bélanger-Champagne, Janina Hohnholz, Boris Stoeber, Cheryl Duzenli and Cornelia Hoehr
Electronics 2024, 13(11), 2211; https://doi.org/10.3390/electronics13112211 - 6 Jun 2024
Viewed by 712
Abstract
Optical fibres are gaining popularity for relative dosimetry in proton therapy due to their spatial resolution and ability for near real-time acquisition. For FLASH proton therapy, these fibres need to handle higher dose rates and larger doses than for conventional proton dose rates. [...] Read more.
Optical fibres are gaining popularity for relative dosimetry in proton therapy due to their spatial resolution and ability for near real-time acquisition. For FLASH proton therapy, these fibres need to handle higher dose rates and larger doses than for conventional proton dose rates. We developed a multi-point fibre sensor embedded in a 3D-printed phantom which can measure the profile of a FLASH proton beam. Seven PMMA fibres of 1 mm diameter were embedded in a custom 3D-printed plastic phantom of the same density as the fibres. The phantom was placed in a proton beam with FLASH dose rates at the TRIUMF Proton Therapy Research Centre (PTRC). The sensor was exposed to different proton energies, 13.5 MeV, 19 MeV and 40.4 MeV, achieved by adding PMMA bolus in front of the phantom and three different beam currents, varying the dose rates from 7.5 to 101 Gy/s. The array was able to record beam profiles in both transverse and axial directions in relative agreement with measurements from EBT-XD radiochromic films (transverse) and Monte Carlo simulations (axial). A decrease in light output over time was observed, which might be caused by radiation damage in the matrix of the fibre and characterised by an exponential decay function. Full article
(This article belongs to the Special Issue Applications of Optical Fiber Sensors)
Show Figures

Figure 1

10 pages, 2500 KiB  
Article
Application of a Portable Colorimeter for Reading a Radiochromic Film for On-Site Dosimetry
by Hiroshi Yasuda and Hikaru Yoshida
Appl. Sci. 2023, 13(8), 4761; https://doi.org/10.3390/app13084761 - 10 Apr 2023
Cited by 7 | Viewed by 2009
Abstract
Radiochromic films have widely been used for quality assurance (QA) in radiation therapy and have many advantageous features such as self-developing visible coloration, wide dose range and easiness to handle. These features have a good potential for application to other fields associated with [...] Read more.
Radiochromic films have widely been used for quality assurance (QA) in radiation therapy and have many advantageous features such as self-developing visible coloration, wide dose range and easiness to handle. These features have a good potential for application to other fields associated with high-dose radiation exposure, e.g., verification of various radiation sources used in industry and research, occupational radiation monitoring as a preparedness for radiological emergencies. One of the issues in such applications is the elaborate process of acquisition and analyses of the color image using a flatbed scanner and image processing software, which is desirably to be improved for achieving a practical on-site dosimetry. In the present study, a simple method for reading a radiochromic film by using a portable colorimeter (nix pro 2; abbreviated here “Nix”) was proposed and its feasibility for diagnostic X-rays was tested with a commercial radiochromic film (Gafchromic EBT-XD). It was found that the color intensities of red and green components of EBT-XD were successfully measured by Nix over a wide dose range up to 40 Gy. Though some angle dependence was observed, this error could be well averted by careful attention to the film direction in a reading process. According to these findings, it is expected that the proposed on-site dosimetry method of combining a radiochromic film and a portable colorimeter will be practically utilized in various occasions. Full article
Show Figures

Figure 1

11 pages, 1684 KiB  
Article
Characterization of Ultra-High-Dose Rate Electron Beams with ElectronFlash Linac
by Lucia Giuliano, Gaia Franciosini, Luigi Palumbo, Lilia Aggar, Marie Dutreix, Luigi Faillace, Vincent Favaudon, Giuseppe Felici, Federica Galante, Andrea Mostacci, Mauro Migliorati, Matteo Pacitti, Annalisa Patriarca and Sophie Heinrich
Appl. Sci. 2023, 13(1), 631; https://doi.org/10.3390/app13010631 - 3 Jan 2023
Cited by 14 | Viewed by 2817
Abstract
Purpose: The electron linac ElectronFlash installed at Institut Curie (Orsay, France) is entirely dedicated to FLASH irradiation for radiobiological and pre-clinical studies. The system was designed to deliver an ultra-high-dose rate per pulse (UHDR) (above 106 Gy/s) and a very high average [...] Read more.
Purpose: The electron linac ElectronFlash installed at Institut Curie (Orsay, France) is entirely dedicated to FLASH irradiation for radiobiological and pre-clinical studies. The system was designed to deliver an ultra-high-dose rate per pulse (UHDR) (above 106 Gy/s) and a very high average dose rate at different energies and pulse durations. A campaign of tests and measurements was performed to obtain a full reliable characterizations of the electron beam and of the delivered dose, which are necessary to the radiobiological experiments. Methods: A Faraday cup was used to measure the electron charges in a single RF pulse. The percentage depth dose (PDD) and the transverse dose profiles, at the energies of 5 MeV and 7 MeV, were evaluated employing Gafchromic films EBT-XD for two Poly-methylmethacrylate (PMMA) applicators with irradiation sizes of 30 mm and 120 mm, normally used for in vivo and in vitro experiments, respectively. The results were compared with Monte Carlo (MC) simulations. Results: The measurements were performed during a period of a few months in which the experimental set up was adapted and tuned in order to characterize the electron beam parameters and the values of delivered doses before the radiobiological experiments. The measurements showed that the dose parameters, obtained at the energy of 5 MeV and 7 MeV with different applicators, fulfill the FLASH regime, with a maximum value of an average dose rate of 4750 Gy/s, a maximum dose per pulse of 19 Gy and an instantaneous dose rate up to 4.75 ×106 Gy/s. By means of the PMMA applicators, a very good flatness of the dose profiles was obtained at the cost of a reduced total current. The flatness of the large field is reliable and reproducible in radiobiological experiments. The measured PDD and dose profiles are in good agreement with Monte Carlo simulations with more than 95% of the gamma-index under the thresholds of 3 mm/3%. Conclusions: The results show that the system can provide UHDR pulses totally satisfying the FLASH requirements with very good performances in terms of beam profile flatness for any size of the fields. The monitoring of electron beams and the measurement of the dose parameters played an important role in the in vivo and in vitro irradiation experiments performed at the Institut Curie laboratory. Full article
(This article belongs to the Special Issue Medical Physics: Latest Advances and Prospects)