Date Submitted: Mar 19, 2024
Open Peer Review Period: Mar 20, 2024 - May 15, 2024
(currently open for review)

Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.

The measurement of vital signs in pediatric patients by Lifelight® software in comparison to the standard of care: the VISION-Junior observational study protocol

  • Gauri Misra; 
  • Simon Wegerif; 
  • Louise Fairlie; 
  • Melissa Kapoor; 
  • James Fok; 
  • Gemma Salt; 
  • Jay Halbert; 
  • Ian Maconochie; 
  • Niall Mullen

ABSTRACT

Background:

Measuring vital signs (VS) is important in potentially unwell children, as a change in VS may indicate a more serious infection than is clinically apparent or herald clinical deterioration. However, currently available methods are not suitable for regular measurement of VS in the home or community setting, and adherence can be poor. The COVID-19 pandemic highlighted a need for the contactless measurement of VS by non-clinical personnel, reinforced by the growing use of virtual medicine. Lifelight® is an app being developed as a medical device for the contactless measurement of VS using remote photoplethysmography via the camera on smart devices. The VISION-D (Measurement of Vital Signs by Lifelight® Software in Comparison to the Standard of Care – Development) and -V (Validation) studies demonstrated the accuracy of Lifelight compared with standard of care measurement of blood pressure, pulse rate, and respiratory rate in adults, supporting certification of Lifelight as a class I Conformité Européenne (CE) medical device.

Objective:

To support further development of the Lifelight app, the VISION-Junior study (clinicaltrials.gov identifier NCT05850013) is collecting high-quality data to enable the accurate measurement of VS (pulse rate, respiratory rate and oxygen saturation) in pediatric patients.

Methods:

The study is recruiting pediatric patients (age <18 years) attending the Sunderland Royal Hospital Paediatric Emergency Department of the South Tyneside and Sunderland NHS Foundation Trust. High-resolution videos of the face (and torso in children aged <5 years) and audio recordings (to explore the value of cry, wheeze, cough, and other sounds in predicting illness) are made using the Lifelight Data Collect app. VS are measured simultaneously using standard of care methods (finger clip sensor for pulse rate and oxygen saturation; manual counting of respiratory rate). Feedback from patients, parents/carers, and nurses who use Lifelight is collected via questionnaires. Anticipated recruitment is 500 participants, with sub-targets for age, sex, and skin tone distribution (Fitzpatrick six-point scale). Early data will be used to refine the Lifelight algorithms. A separate dataset will be retained to test the performance of Lifelight against predefined targets.

Results:

A total of 303 participants were recruited from June to December 2023; recruitment will continue until March 2024. Algorithm refinement is in progress. The performance of Lifelight compared with standard of care measurement of VS will then be tested. Recruitment will resume if further data are required. The analyses are expected to be completed by mid-April 2024.

Conclusions:

This study will collect data that enable development of Lifelight for the measurement of VS in pediatric patients. Clinical Trial: ClinicalTrials.gov NCT05850013 https://clinicaltrials.gov/study/NCT05850013


 Citation

Please cite as:

Misra G, Wegerif S, Fairlie L, Kapoor M, Fok J, Salt G, Halbert J, Maconochie I, Mullen N

The measurement of vital signs in pediatric patients by Lifelight® software in comparison to the standard of care: the VISION-Junior observational study protocol

JMIR Preprints. 19/03/2024:58334

DOI: 10.2196/preprints.58334

URL: https://preprints.jmir.org/preprint/58334

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.

Advertisement